Dell EMC PowerSwitch S5148F-ON Manual de instalación - Página 27

Navegue en línea o descargue pdf Manual de instalación para Interruptor Dell EMC PowerSwitch S5148F-ON. Dell EMC PowerSwitch S5148F-ON 45 páginas.
También para Dell EMC PowerSwitch S5148F-ON: Manual de instalación (20 páginas)

Dell EMC PowerSwitch S5148F-ON Manual de instalación
4. Remove the switch from the rack.
At the same time, press in the two side-release bars on the switch and slide the switch forward.
If you are using the fan trays or PSUs in the replacement switch, remove them from the switch.
5. Unpack the new switch.
6. Confirm that the software version of the replacement switch is the same as the previously installed switch.
show os-version
If the software versions do not match, upgrade the replacement switch software using the procedure included with the
firmware download.
7. Copy the backed-up switch configuration to the new switch.
copy tftp://hostip/filepath running-config
8. Install the new switch in your rack or cabinet.
For detailed installation instructions, see
If you are using the fan trays or PSUs from the removed switch, reinsert them in the replacement switch.
9. Connect all the cables.
10. Power on the switch.
For more information, see
S5148F-ON switch
Switch power
up.
installation.
S5148F-ON switch installation
27