Dell PowerConnect B-DCX-4S Backbone Procedimiento de sustitución - Página 6
Navegue en línea o descargue pdf Procedimiento de sustitución para Interruptor Dell PowerConnect B-DCX-4S Backbone. Dell PowerConnect B-DCX-4S Backbone 16 páginas. Power supply and filler
panel
También para Dell PowerConnect B-DCX-4S Backbone: Procedimiento de sustitución (6 páginas)
CP0
Ethernet IP Address: 10.32.50.10
Ethernet Subnetmask: 255.55.0.0
HostName : cp0
Gateway Address: 10.32.40.1
CP1
Ethernet IP Address: 10.32.50.11
Ethernet Subnetmask: 255.55.0.0
HostName : cp1
Gateway Address: 10.32.40.1
Backplane IP address of CP0 : 10.0.0.4
Backplane IP address of CP1 : 10.0.0.5
switch:admin>switch:admin>
5. Display and record the manufacturer serial numbers.
Enter chassisShow; then, copy the command output into the "config-miscinfo.txt" file on a workstation.
"Factory Serial Num" and "Serial Num" are listed under "Chassis/WWN Unit 1." If the current WWN cards are
the original cards, the factory serial number listed is the same as the chassis serial number.
switch:admin> chassisshow
Chassis Backplane Revision: 1F
SW BLADE
Slot: 1
Header Version:
Power Consume Factor:
Factory Part Num:
Factory Serial Num:
Manufacture:
Update:
Time Alive:
Time Awake:
<output truncated>
CHASSIS/WWN
Unit: 1
Header Version:
Power Consume Factor:
Factory Part Num:
Factory Serial Num:
Manufacture:
Update:
Time Alive:
Time Awake:
<output truncated>
switch:admin>
6. Create a SAN "profile" by entering and recording the information provided by the following commands:
•
nsShow
•
nsAllShow
6
2
-50
60-0001532-03
KP000000195
Day:
1
Month:
1
Year: 2007
Day: 14
Month:
3
Year: 2012
187 days
3 days
(in same assembly as WWN Unit: 2)
2
-3
60-0001501-07
FT02X805BE2
Day: 26
Month:
3
Year: 2007
Day: 14
Month:
3
Year: 2009
207 days
3 days
PowerConnect B-DCX-4S Chassis Replacement Procedure
53-1001800-01