Fault
Light on, but motor does not
work
Light does not work, motor
does not work
Liquid dripping
Shake of the body
Insufficient suction
The machine inclines
(7) TROUBLE SHOOTING
Cause
The flue blocked
The capacitor damaged Replace
The motor jammed bearing
damaged
Beside the above mentioned, check the following:
Light damaged
Power cord looses
Air ventilation entrance are
not tightly sealed
Leakage from the connection
of chimneys and cover
The motor is not tightly
hanged
The body is not tightly
hanged
The distance between the
body and the ducting outlet is
too long
Too much ventilation from
open doors or windows
The fixing screw not tight
enough
The hanging screw not tight
enough
Solution
Clear the blockage
capacitor
Replace motor
Replace lights
Connect the wires as per
the electric diagram
Reseal
Take chimneys down and
seal
Lock the motor tightly
Fixed the body tightly
Readjust the distance
Choose a new place and
reinstall range hood
Tighten the hanging
screw to return back to
horizontal position
Tighten the hanging
screw to return back to
horizontal position