4. Remove the UV filter and set on a clean, lint free cloth. For removal procedures, see the
projector service manual.
If the filter is yellow, replace it. When replacing the UV filter make sure the directional arrow
on the filter faces the reflector.
5. To prepare the Techspray 1671-10S canister for use, firmly attach the red output tube to the
output nozzle on the canister, point the canister away from the UV filter, and press the trigger
rapidly 3 times to clear any possible impurities from the tube.
6. To clean the UV filter, hold the filter by its edges and press the trigger of the Techspray canister
rapidly 3 times, 6 inches above the UV filter.
You must hold the Techspray canister vertically. Holding the canister at an angle can release
liquid refrigerant and contaminate the UV filter.
7. Turn the UV filter over and repeat step 6.
8. If the UV filter still appears dirty:
a) Place the filter on a clean and dry lint free cloth.
b) Dampen a clean, folded lint free cloth with acetone and wipe the surface carefully. Do not
apply pressure with your fingers. Use only the tension in the folded cloth.
c) Allow the solvent to dry.
d) Turn the UV filter over and repeat step b.
9. Reassemble the projector and connect it to AC power.
Cleaning the projection lens
Learn the steps for cleaning the input and output ends of the projection lens.
If you do not have additive-free compressed air, use an air bulb or a camel hair brush to remove dust
and debris. If you have questions about the cleaning methodology, contact Christie.
1. Prepare the projector for service. For more information, see Preparing the projector for service
(on page 3).
2. Put on a pair of powder-free latex gloves.
3. Remove the projection lens from the projector and place it on a flat, stable surface. For
removal procedures, see the projector service manual.
4. To prepare the Techspray 1671-10S canister for use, firmly attach the red output tube to the
output nozzle on the canister, point the canister away from the optical component, and press
the trigger rapidly 3 times to clear any possible impurities from the tube.
5. To clean the input end of the projection lens, press the trigger of the Techspray canister rapidly
3 times, 6 inches above the optical component.
You must hold the Techspray canister vertically. Holding the canister at an angle can release
liquid refrigerant and contaminate the projector optics.
6. If the input end of the lens still appears dirty:
a) Dampen a clean, folded lint free cloth with acetone and wipe the surface of the input end
of the lens carefully with the smooth portion of the cloth that has no folds or creases.
b) Inspect the input end of the lens with a bright light and verify no streaks appear. If streaks
are present, repeat step a.
7. Reinstall the lens.
Cleaning Projector Optics Technical Bulletin
020-200298-04 Rev. 1 (08-2017)
Copyright
2017 Christie Digital Systems USA Inc. All rights reserved.
©