Miele PW 5105 EL Plan de instalaciones - Página 12

Navegue en línea o descargue pdf Plan de instalaciones para Lavadora Miele PW 5105 EL. Miele PW 5105 EL 16 páginas.
También para Miele PW 5105 EL: Plan de instalaciones (13 páginas)

Miele PW 5105 EL Plan de instalaciones
Cold water
Min. flow pressure
(Soft water)
Max. pressure
Max. throughput
On-site connection thread
Length of connection hose (supplied: 1 connection hose)
Hourly water demand (average for 60°C program) for
standard connection (with hot and cold water)
If hot water supply is not available add hot water demand to
cold water demand.
Warm water
Max. temperature
(Soft water)
Min. flow pressure
Max. pressure
Max. throughput
On-site connection thread
Length of connection hose
(supplied: 1 connection hose)
Hourly water demand (average for 60°C program)
Machine can be connected to a hot water supply line with a
temperature of 70°C to max. 85°C. This requires a separate
inlet hose. This additional inlet hose is available from Miele
Spares. The machine must also be reprogrammed by Miele
Service.
If hot water is not available, connect hot water hose to cold
water valve!
Drain: Dump
Max. temperature
AV
valve
Machine-side drain connection (ext. diameter)
On-site drain (int. diameter)
Max. transient throughput
Vented drainage required. If ventilation is insufficient, fit Miele
kit, Mat. no. 05238090.
Drain manifolds serving several machines must be of
sufficient cross-section.
Fittings for
Miele base UG/UO 5010
base/floor
4 × metal angled brackets
installation
(to secure machine to base )
4 × screws DIN 571 (Ø × length)
4 × rawl plugs (Ø × length)
Machine must be bolted to the base and floor!
Fixing materials for a floating screed floor are to be provided
on site.
Installation on floor or concrete base
2 × clamps
2 × screws DIN 571 (Ø × length)
2 × rawl plugs (Ø × length)
Machine must be bolted to the base or floor. Fittings are
supplied with machine
Fixing materials for a floating screed floor are to be provided
on site.
Technical datasheet: PW5105 EL AV (Dump valve)
Date: 01.2015
14.5 psi
100 kPa
145 psi
1000 kPa
2.9 gal/min
11 l/min
¾" garden hose
¾" garden hose
thread, male
thread, male
61"
1550 mm
approx. 18.5
approx. 70 l/h
gal/h
158°F
70°C
14.5 psi
100 kPa
145 psi
1000 kPa
2.9 gal/min
11 l/min
¾" garden hose
¾" garden hose
thread, male
thread, male
61"
1550 mm
approx.
approx. 70L/h
18.5 gal/h
158°F
70°C
2 15/16"
75 [DN 70] mm
2 15/16"
75 [DN 70] mm
16.4 gal/min
62 l/min
5/16" x 2 9/16"
8 x 65 mm
½" x 2 3/8"
12 x 60 mm
¼" x 2"
6 x 50 mm
5/16" x 1 9/16"
8 x 40 mm
Page: 12