Miele PW 6131 D Plan de instalaciones - Página 10

Navegue en línea o descargue pdf Plan de instalaciones para Lavadora Miele PW 6131 D. Miele PW 6131 D 10 páginas.

Miele PW 6131 D Plan de instalaciones
Drainage via
dump valve
Foam vent
Fittings (supplied)
Special product
WI:
Machine data
Installation should only be carried out by authorized installers in accordance with all local and national regulations!
Observe installation instructions when installing machine! All rights reserved!
Installation plan PW 6131 Steam
Date 19.10.2007
Max. temperature
Machine drain connection (d
a
On-site drain connection (d
)
i
Max. throughput
Vented drainage required. If ventilation is insufficient, fit
Miele kit, Mat. no. 05238090.
Drain manifolds serving several machines must be of
sufficient cross-section.
A drainage system for foam escaping from the drain
vent can be built using standard drain pipe sections.
A 87° branch with an end cap should be provided for
this purpose.
Miele plinth UG/UO 6013
4 × metal angled brackets (to secure machine to plinth)
4 × screws (Diameter × length)
4 × wall anchors (Diameter × length)
Machine must be secured!
Fixing materials provided for securing to concrete floor
On concrete platform
2 × screws (Diameter × length)
2 × wall anchors (Diameter × length)
Machine must be secured!
Fixing materials provided for securing to concrete floor
Without plinth
2 × screws (Diameter × length)
2 × wall anchors (Diameter × length)
Machine must be secured!
Fixing materials provided for securing to concrete floor
On concrete platform
4 × screws (Diameter × length)
4 × wall anchors (Diameter × length)
Machine must be secured!
Fixing materials provided for securing to concrete floor
Without plinth
4 × screws (Diameter × length)
4 × wall anchors (Diameter × length)
Machine must be secured!
Fixing materials provided for securing to concrete floor
Width
Depth
Height
Knocked-down dimensions (Width)
Recommended clearance to rear wall
(to machine front edge)
Net weight
Dynamic floor load during operation, max.
Static load, max.
Dynamic load max.
Drum frequency, max.
Average heat dissipation
(depending on room temperature and selected program)
203 °F
× s × l)
3" x 1/16" x 3 9/16"
3"
5/16" x 3 1/8"
1/2" x 2 3/8"
5/16" x 3 1/8"
1/2" x 2 3/8"
5/16" x 3 1/8"
1/2" x 2 3/8"
5/16" x 3 1/8"
1/2" x 2 3/8"
5/16" x 3 1/8"
1/2" x 2 3/8"
31 5/8"
35 13/16"
49 3/16"
31 7/8"
63"
763 lbs
4,304 N
3,801 N
503 N
1,470 W
USA
95 °C
75×1,9×90 mm
75 mm
52.8 gal/min
200 l/min
8 × 80 mm
12 × 60 mm
8 × 80 mm
12 × 60 mm
8 × 80 mm
12 × 60 mm
8 × 80 mm
12 × 60 mm
8 × 80 mm
12 × 60 mm
804 mm
910 mm
1.250 mm
810 mm
1.600 mm
346 kg
4.304 N
3.801 N
503 N
18.3 Hz
18,3 Hz
1.470 W
CDN
Page 9