en - Installation and planning notes
6
The washing machine must be connected to an electrical supply
that complies with local and national regulations. Please also observe
your insurance and energy supplier's regulations as well as any health
and safety at work regulations.
The required voltage, power consumption and specifications for
external fusing are quoted on the data plate on the washing machine.
Ensure that the supply voltage complies with the voltage quoted on
the data plate before connecting the washing machine to the power
supply.
Connection to a supply voltage other than the one quoted on the
data plate can lead to functional faults and damage the washing
machine.
If more than one voltage is quoted on the data plate, the washing
machine can be converted for connection to the voltages stated.
Conversion to a different voltage must only be carried out by a
Miele Service engineer or by an authorized Service Dealer. The wiring
instructions given on the wiring diagram must be followed.
The washing machine can either be hard-wired or connected via a
plug and socket that complies with national codes and regulations.
For a hard-wired connection an all-pole isolation device must be in-
stalled on site.
For hard-wired machines connection should be made via a suitable
switch with all-pole isolation which, when in the off position, ensures
a 1/8" (3 mm) gap between all open contacts. These include circuit
breakers, fuses and relays.
If the power supply cannot be permanently disconnected, the isolator
switch (including plug and socket) must be safeguarded against be-
ing switched on either unintentionally or without authorization.
Tip: We recommend connection to the power supply via a suitable
plug and socket which must be easily accessible for servicing and
maintenance work after the machine has been installed.
If it is necessary to install a residual current device (RCD) in accor-
dance with local regulations, a type B residual current device (sensi-
tive to universal current) must be used.
An existing type A residual current device (RCD) must be exchanged
for a type B RCD.
If necessary, equipotential bonding with good galvanic contact
must be guaranteed in compliance with all applicable local and na-
tional installation specifications.
Equipotential bonding must have an ground current rating >10 mA.
Accessories for equipotential bonding are not supplied and need to
be ordered separately.