SERIAL NUMBER 14-000001 AND UP
Reset Safety Thermostat fault:
**Safety thermostat is a protection for the high limit. If the fan has failed or heater shut down
incorrectly it creates trapped heat which trips the thermostat.**
❏ Look for the black cap on the heat exchanger below the main blower fan.
(Example "A")
❏ Remove the cap and you will expose a red button. This button is
connected to the safety thermostat and has to be reset. Push and hold for
five seconds.
❏ If the thermostat continues to trip then give it 5 to 10 minutes for the heat
to dissipate.
❏ If the problem persists then replace the safety thermostat.
❏