Installation diagram

Lack of or insufficient residual-current circuit breaker.
Danger of fatal electric shock!
Installation of a class B all-current-sensitive residual-current circuit breaker with a release cur-
Danger
rent of 30 mA (DIN VDE 0664) before the machine is put into operation for the first time.
* Considering the local conditions, the exact
dimensions must be determined.
The dimensions of the machine can be found
on page 1.
A
Waste water connection
EZ
Electrical connection
TWw
Fresh water connection
Requirements for on-site installation
Fresh water connection (G ¾", external thread)
Position
Water quality
Water inlet temperature
Water hardness
Minimum flow pressure
Maximum inlet pressure
Flow rate
Waste water connection
Position
Construction
Page 2
appr. 400 mm above finished floor
next to the machine
The fresh water must in microbiological aspects have the quality of drinking
water.
max. 60 °C
 3 °dH (3.8 °e, 5.34 °TH, 0.54 mmol/l, 3 gr/gal) (recommendation, to prevent
scaling of the machine)
 30 °dH (37.6 °e, 53.4 °TH, 5.35 mmol/l, 30 gr/gal) with machines with an
internal water softener
100 kPa (1.0 bar)
600 kPa (6.0 bar)
at least. 4 l/min
max. 600 mm above finished floor
next to the machine
Trap on site
English
Important!
Provide the local connections on the left or the
right beside the machine.
Observe both the local and country-specific
regulations when conducting electrical and
hydraulic connection work.
Only when the local mains disconnector is
switched off, the machine is without power.
Involve the machine in equipotentiaal bonding.
Supply hose
Old existing hoses may not be re-used.
The supply hose may not be shortened or
damaged.
Electrical supply pipe (Type H07 RN-F)
If the mains cable of this machine is damaged, it
must be replaced by the manufacturer or his
Customer Service or another qualified person in
order to prevent hazards. The mains cable must
be H07 RN-F type or equivalent.
M.-Nr. 10416210; 27.11.2015; msch; 89013416-en