Allmatic SCOR.AS Manual - Página 6

Navegue en línea o descargue pdf Manual para Unidad de control Allmatic SCOR.AS. Allmatic SCOR.AS 8 páginas. For barriers bevk 1 motor 24vcc

Allmatic SCOR.AS Manual
13. Advanced functions
Through the 8-position dip switch, it is possible to personalize further the automation functions. As standard the control panel leaves the factory
with all the main functions already set, however, it is always possible to modify them by following the table:
Dip No.
1
2
3
4
5
S.STEP input functioning
6
7
8
velocity of the automation
13.1 Modality of functioning
Setting the dip n° 1 on ON and the dip n° 2 on OFF, the manual functioning is enabled. This functioning allows the displacement of the wing with
the red and blue keys present on the card (see section 4)
13.2 Strokes learning
Setting the dip n° 1 on OFF and the dip n° 2 on ON, t he learning of the strokes is enabled. This functioning allows to learn the courses and the
phase shift of the wings (see section 6).
Setting the dip n° 1 on ON and the dip n° 2 on ON, the pedestrian opening is enabled. This functioning allows to learn the opening of the first wing
when the pedestrian opening key is pressed (see section 11).
13.3 Pre – flashing
Setting the dip nr.3 on ON the pre – flashing is enabled. This function means that before any movement there will be a brief flashing in order to
indicate the movement is about to begin. Remember to turn the control unit off and then on again after modifying the dip switch's configuration.
13.4 Condominium function
Every command sent via radio or with the step by step buttons and/or pedestrian buttons will only open the automation. Reclosure is entrusted to
the automatic reclosure function, which must be activated since all closure command are ignored. In case the condominium function is active and
the automatic reclosure is deactivated by means of the respective regulation trimmer (turned completely in clockwise sense), the control panel
puts itself in state of signalled alarm, with door closed, through fast blinkings of the flashing light. Set dip n° 4 on ON to activate the condominium
function.
13.5 Functioning of wired input PP
Setting the dip n° 5 on OFF the wired input Step by Step is enabled.
Setting the dip n° 5 on ON the wired input Open is enabled.
13.6 Photocells check
This control unit is equipped with a function which allows you to carry out a check of the photocells operation before any turning on of the motor. In
this way there is the possibility of increasing the safety of the system in case of photo device damaging (for example output relay stuck) or of an
unwanted short – circuit on the photocell input. In case of breakdown, the control panel will signal it through a single flashing when a key is
pressed and no movement will take place. This check is carried out after the control panel has received an order to move, but therefore powering
the motor. Set dip n° 6 on ON to activate the photo cell check.
13.7 Clock function
Setting the dip n° 7 on ON the timing function is a ctivated. The rib input becomes timing input where it is possible to connect a timer for the
programming opening of the gate. The contact is interpreted as request of opening and of permanence on the opening state until the contact
remains closed. When the contact opens, the gate automatically closes.
13.8 Velocity of the automation
The control unit SCOR.AS BEVK can work at 2 speeds. This setting is carried out positioning the dip nr.8 on OFF if you want the functioning at
reduced speed and on ON if you want the functioning at maximum speed. This setting MUST be carried out BEFORE of the learning of the strokes.
WARNING: The adjustments must be carried out so that it is possible to declare the conformity according to the Machine
Directive 98\37\CE and particularly to the EN 12445; EN 12453 ed EN 12635 regulation and successive modifications.
14. Modality of photocells intervention
The modality of photocells intervention is only one:
The photocells do not intervene on opening, while they immediately invert the movement until the complete re opening in case of obstacle
in closing.
15. Modality of ribs intervention
The modality of rib intervention is only one:
The rib does not intervene on opening, while it immediately inverts the movement until the complete re – opening in case of obstacle on
closing.
WARNING: WITH THE DIP 7 ON ON THE RIB INPUT BECOMES CLOCK INPUT. TO UTILIZE THE RIB, PUT THE CONTACT OF THE RIB IN
SERIES WITH THE CONTACT OF THE PHOTOCELLS OR WITH THE STOP.
6-1622381
rev.2
04/02/2016
function
modality of functioning
Strokes learning
Pre-flashing
Condominium function
Photocell check
Clock function
ITA
Dip OFF
Automatic
disabled
Not active
Not active
Step by step
disabled
Not active
Reduced
ENG
FRA
ESP
DEU
POR
Dip ON
Manual
enabled
Active
Active
Open
enabled
Active
Maximum
Pag 6 di 8