Installation

AWG 102

The AWG 102 external motor is
designed to be installed on an outside
wall.
The external motor must be installed
on the outside wall in a vertical
position only.
The extraction outlet must face
downwards.
The external motor is connected to the
cooker hood by means of a control
cable and is operated by the control
panel on the cooker hood.
Please refer to the operating and
installation instructions for the
cooker hood before installing the
external motor and ducting.
8
^ Unscrew the 2 fixing screws on the
underside of the appliance and take
the motor unit off of its fixing bracket.
^ The ducting stub on the motor unit
has a diameter of 125 mm when the
appliance is supplied.
If a diameter of 150 mm is required,
the front ring of the stub must be cut
off at the join with a sharp knife (see
illustration).