Installation
For air extraction mode
For 150 mm exhaust ducting, cut
the exhaust socket to size with a
sharp knife.
For 125 mm exhaust ducting, the
exhaust socket is installed as it is.
If required, install the non-return flap.
Check that the flap opens easily and
closes by itself.
32
Secure the exhaust ducting to the
exhaust connection, e.g. with a hose
clip (available as an optional
accessory) on flexible ducting.
Insert the exhaust socket into the
exhaust opening and secure it by
turning clockwise.
See "Connection for air extraction"
for further instructions on fitting the
ducting.
For recirculation mode
Fit the charcoal filter (see "Cleaning
and care").