Miele DA 220-2 EXT Manual de funcionamiento e instalación - Página 28
Navegue en línea o descargue pdf Manual de funcionamiento e instalación para Campana de ventilación Miele DA 220-2 EXT. Miele DA 220-2 EXT 36 páginas. Cooker
^ Prepare the ceiling plate for fitting. In-
sert the two spring retainers from be-
low into the slots provided in the ceil-
ing plate.
^ Pull the mains connection cable
through the ceiling plate.
^ Insert the four countersunk screws
M 6 x 20 into the recessed holes from
above. Secure the screws from
above with some adhesive tape to
prevent them from being pushed up-
wards when the nuts are tightened.
28
^ Screw the ceiling plate to the ceiling
with the 8 x 60 mm screws and wash-
ers.
^ For appliances connected to an ex-
ternal fan, model designation...EXT:
Make the connection between the
cooker hood and the external fan with
the 6-pole connector.
Then feed the connection cable to-
gether with plug connectors through
the cut out into the ceiling space.