Miele DA 230-2 Manual de funcionamiento e instalación - Página 24
Navegue en línea o descargue pdf Manual de funcionamiento e instalación para Campana de ventilación Miele DA 230-2. Miele DA 230-2 32 páginas. Cooker
Then feed the connection cable to-
gether with plug connectors through
the cut out into the ceiling space.
^ Assemble the tower. Place the flange
plate of the tower onto the ceiling
plate in such a way that the spring
clips click into the slots securely.
^ Screw the flange plate securely to the
ceiling plate with the four M6 nuts
supplied.
24
^ Shorten the cable for electrical con-
nection as much as possible and se-
cure inside the cooker hood tower
with cable clips.
Before connecting the appliance
read the safety notes in "Warning
and Safety instructions" and in the
"Electrical connection" section.
^ Finally, push the cover plate upwards
until the spring fixing clips click in se-
curely and the frame lies tightly
against the ceiling.
^ Before using the appliance for the
first time take the grease filter out and
remove the protective foil from the fil-
ter frame. Then replace the filter.