Installation recommendations

– When deciding on the safety
distance between the hob and
cooker hood, please note that a
distance of 650 mm above electric
cookers/hobs may be preferable to
give more working space under the
hood.
– Account should also be taken of the
height of the person who will be
using the hood most often. They
should have sufficient space to work
comfortably at the hob, and be able
to reach the hood controls with ease.
– Please be aware that if positioned
too high, extraction will be inefficient.
– To achieve optimum vapour
extraction, the cooker hood must
cover the hob. It should be
positioned centrally over the hob, not
to the side.
– The hob should be no wider than the
cooker hood, and if possible, it
should be narrower.
– The installation area must be easily
accessible. The cooker hood should
be easily accessible and easy to
dismantle in the event that service is
required. This should be taken into
consideration when planning the
position of cupboards, shelves,
ceilings or features in the vicinity of
the cooker hood.
28
Drilling diagram for wall
mounting
 Please follow the directions given in
the installation instructions supplied
for drilling.
 For pre-installation of a back wall
where the holes have to be pre-
drilled, please refer to the drilling
distances in the drawing above
(screws  5 mm).
*The dimension for the middle wall
bracket is variable. It will depend on the
position of the wall vent and the socket.
It should be set as low as possible.