Installation
The extractor is designed to be built
into a chimney type cooker hood hous-
ing.
Cut-out dimensions: 670 x 370 mm
Connection for air extraction must
be carried out only by a competent
person.
The following minimum distances
must be maintained between the
cooker hood and the hob:
– 55 cm for electric hobs
– 65 cm for gas hobs (see also
Warning and Safety section)
Safety regulations prohibit the fitting
of a cooker hood over solid fuel
stoves.
Fitting adapter (Diameter
100 mm or 120/125 mm )
Place one of the adapters (supplied)
(appropriate for the diameter of the
ducting) onto the exhaust stub and
lock into place.
Building in
Place the appliance in the cut-out
from below and align.
Secure the cooker hood to the hous-
ing with the screws.
Removing the appliance
Unscrew the retaining screws and
remove the cooker hood.
Installation
15