Miele DAS 4620 Manual de instalación - Página 6

Navegue en línea o descargue pdf Manual de instalación para Campana de ventilación Miele DAS 4620. Miele DAS 4620 10 páginas.

Miele DAS 4620 Manual de instalación

Safety distance between hob and cooker hood (S)

When planning the installation height of your cooker hood, the minimum safety
distance between the top of a cooker or hob and the bottom of the cooker hood
is as follows, unless a greater distance is specified by the manufacturer of your
cooking appliance.
See "Warning and Safety" instructions for further information.
Cooking appliance
Electric hob
Electric grill, deep fat fryer (electric)
Multi-burner gas hob,
total output ≤ 12.6 kW, no burner > 4.5 kW
Multi-burner gas hob,
total output > 12.6 kW and ≤ 21.6 kW,
no burner > 4.8 kW.
Multi-burner gas hob,
total output > 21.6 kW,
or multi-burner gas hob where one burner > 4.8 kW.
Single burner gas hob, output ≤ 6 kW.
Single burner gas hob, output > 6 kW and ≤ 8.1 kW.
Single burner gas hob, output > 8.1 kW
If you are fitting a front panel made of wood or plastic to the cooker hood,
observe the safety distances given by the hob manufacturer regarding the use
of easily flammable materials.
12062340-01
Installation
Minimum distance S
450 mm
650 mm
650 mm
760 mm
Not possible
650 mm
760 mm
Not possible