Miele T 1576 VENT ED DRYER - OPERATING Manual de instrucciones - Página 30

Navegue en línea o descargue pdf Manual de instrucciones para Secadora Miele T 1576 VENT ED DRYER - OPERATING. Miele T 1576 VENT ED DRYER - OPERATING 40 páginas. Vented dryer

Miele T 1576  VENT ED DRYER - OPERATING Manual de instrucciones
The overall duct length will determine
the duct diameter.
^ Measure the actual duct length
needed:
1. Establish the number of elbows or
bends necessary, noting the type of
bend, angle and radius involved
(see, Table 1).
2. Add the additional duct length as
specified in Table 1 to the actual
duct length to get the effective duct
length.
3. The necessary duct diameter can
then be found in Table 2.
Drying times and energy consumption
remain unaltered for 4" (100 mm) duct
up to a total length of 66 ft. (20 m).
Longer ducts may lead to slight
increases, but, the function will not be
impaired as long as the necessary duct
diameter is used (Table 2).
26
Flexible
90 °
metal duct
45 °
Smooth
90 °
metal duct
Elbow 90°
90 °
sharp;
no radius
Concertina
90 °
bend
Wall vent kit
with louvres
or
window
vent kit
Wall vent kit
with flap or
window
vent kit
Exhaust
connection
left side
4"
100
5"
125
6"
150
up to
40.6
20"
50.8
16"
up to
40.6
12"
30.5
16"
4"
10
14"
35.6
90"
228.5
8"
20.3
28"
71.1
142" 360.7
99"
251.5
193" 490.2
0 - 66
0 - 20
66 - 100
20 - 30
100 - 140
30 - 42.7