Electrical connection

Electrical connection U.K.

All electrical work should be carried out
only by a suitably qualified and compe-
tent person, in strict accordance with
national and local safety regulations.
Ensure power is not supplied to the
appliance while installation work is
being carried out.
The appliance is supplied with a mains
cable (approx. 1.8 m long) for connec-
tion either to a 230-240V single phase
supply or to a 415 V 3-phase + N sup-
ply. The voltage, rated load and fuse
rating are given on the data plate.
Please ensure these match the house-
hold mains supply.
Connection should be made via a suit-
able isolator which complies with
national and local safety regulations,
and the on/off switch should be easily
accessible for servicing work.
For extra safety it is advisable to install
a residual current device (RCD), with a
trip current of 30 Ma (in accordance
with DIN VDE 0664, DIN VDE 0100 Sec-
tion 739).
When switched off there must be an all-
pole contact gap of 3 mm in the isola-
tor switch (including switch, fuses and
relays acc. to VDE 0660.
Electrical connection
Important
The wires in the mains lead are col-
oured in accordance with the following
code:
Green/yellow = earth
Blue
= neutral
Brown
= live
WARNING:
THIS APPLIANCE
MUST BE EARTHED
Electrical connection (IRL)
This tumble dryer is supplied as stand-
ard for connection to a 400 V 3-phase
+ N supply. The rated load is 5.4 kW.
Connection should be made via a suit-
able isolator which complies with na-
tional and local regulations, and the
on/off switch should be easily ac-
cessible for servicing work. For extra
safety it is advisable to install a residual
current device with a trip current of
30 mA.
The voltage, rated load and fuse rating
are given on the data plate. Please en-
sure that these match the site mains
supply.
WARNING
THIS APPLIANCE MUST BE
EARTHED.