Turn off the vacuum cleaner and un-
plug it.
Remove the blockage. See "Mainte-
nance".
Wait approx. two minutes before
switching the vacuum cleaner on again.
This will enable the roller brush safety
mechanism to reset itself.
Maintenance
Always switch off the vacuum
cleaner for maintenance work and
unplug the power cord from the wall
socket.
Removing threads and hairs
(Figs. 06, 07 + 08)
Use a pair of scissors to cut any
threads or hairs that have wound
themselves around the roller brush.
Then, run the vacuum cleaner to vac-
uum up the cut pieces.
The roller brush cover can be opened to
remove stubborn soiling or blockages
from inside the Electrobrush.
Loosen both locking screws under-
neath the Electrobrush with a coin
and then remove the roller cover.
The roller brush can then be taken out
of its holder and cleaned. Clean the in-
side area around the roller brush at the
same time.
When refitting the roller brush please
note: (Fig. 09)
The roller bearing has marks on it in the
form of notches.
6
With a new roller brush the end of the
roller bearing with the one notch must
face the base plate (see left-hand illus-
tration). This enables the bristles to
stick out by approx. 1/16" (2 mm). This
is important for good brushing.
When the bristles start to show signs of
wear after prolonged use:
Refit the roller bearing so that the end
with two notches points towards the
base plate (see right-hand illustra-
tion).
Refit the cover over the roller brush
and secure it (Fig. 10).
Tighten the locking screws.
If the bristles on the roller brush are
worn down any more, the roller brush
must be replaced with a new one.
Replacing a drive belt (Fig. 11)
Loosen both locking screws under-
neath the Electrobrush with a coin
and then remove the roller cover (Fig.
07).
Remove the roller brush (Fig. 08).
Unscrew screws a underneath the
Electrobrush and then separate the
lower section b from the top sec-
tion c (Fig. 11).
Replace the drive belt.
Reassemble the Electrobrush in the
reverse order.