Miele Powerbrush SEB 236 Manual de instrucciones - Página 13
Navegue en línea o descargue pdf Manual de instrucciones para Aspiradora Miele Powerbrush SEB 236. Miele Powerbrush SEB 236 25 páginas. Powerbrush
También para Miele Powerbrush SEB 236: Manual de instrucciones (40 páginas), Manual de instrucciones (40 páginas)
The block protection has been
activated because the roller brush is
blocked by a vacuumed up item.
^ Turn off the vacuum immediately and
unplug it from the outlet.
^ Remove the item.
^ Press the Multifunction indicator. The
reset function resets the block
protection back to the start position.
^ Plug in the vacuum and turn it on.
The thermo protection has been tripped
due to blockage of the vacuum ducts.
^ Turn the powerbrush off using the
foot pedal.
^ Turn off the vacuum and unplug it
from the outlet.
^ Check the vacuum ducts.
^ Turn the vacuum on for approximately
five minutes to allow the vacuum air
to cool the powerbrush down.
^ Turn off the vacuum and unplug it
from the outlet.
Waiting approximately 15 seconds,
then reconnect the vacuum and turn it
on. The powerbrush is ready for
operation.
13