2.8
Thermal Performance
The Color Force 12 fixture is equipped with an internal fan to drive the internal cooling system. If the internal temperature of the
Color Force 12 exceeds 75 º C the output of the fixture is reduced for automatic protection. This happens on rare and extreme
conditions when ambient temperature is over 35 º C or the internal fans are blocked or damaged.
The airflow to and from the fan must not be constricted to maintain the maximum operating capacity of the Color Force.
3.
Troubleshooting
Troubleshooting is a process of elimination. First, rule out the other field factors (i.e. bad connections, faulty cables and power
supplies). For technical support and/or parts, please contact your selling dealer or the offices listed in this manual.
Symptom
Fixture does not respond to
DMX control.
Noise from fixture unit.
Low LED output.
4.
Specification
Color Force 12 User Manual
Possible Cause
Set to wrong or different DMX address.
Bad cable connecting DMX control and fixture.
Bad in/through connection between adjacent
fixtures.
Fan malfunction.
Internal temperature is over the limit.
Fan is not working.
www.chroma-q.com
14
Solution
Check DMX address and Mode
settings.
Check/replace DMX run from the
console.
Check fan.
Check "Fan Control" mode.
Check fan.
Check for airflow - to and from the
internal fan.
Check area ventilation.
V1.8 August 2014