Permitted operating parameters
100
90
80
70
60
50
40
30
20
10
0
20
30
40
Ambient temperature [°C]
Fig. 2:
Relative duty cycle (ED) depending on switching frequency and
ambient temperature
6
Switching frequency
6/min
10/min
15/min
50
60
70
english
4.2
Application conditions
Ambient temperature max. +50 °C
Protection class
IP65 in accordance with DIN EN 60529 / IEC
60529 with cable plug, e.g. Bürkert Type 2508
Operating duration
Unless otherwise indicated on the type label,
the solenoid system is suitable for continuous
operation
Important information for functional reliability during con-
tinuous operation: If standstill for a long period at least 1-2
activations per day are recommended.
Service life
High switching frequency and high pressures
reduce the service life
4.2.1 Permitted temperature
Permitted medium temperature depending on body material and
sealing material
PVC Version:
Sealing material
FKM
EPDM
Permitted temperature
-10 ... +50 °C
-10 ... +50 °C