WARNING: To retain seal integrity (and preserve warranty) do not loosen or remove any of the bolts around the perimeter of
the light fixture. There are no serviceable components in the light fixture.
Removal or loosening of any of these bolts will void all warranties.

WIRING STEPS:

1. Once the light fixture has been mounted in place, remove access cover [Fig.5]
2. Install a cord grip to suit the gauge source wiring being used [Fig.6]
a.
cord grip not supplied with light fixture *
b. install as per cord grip manufacturer recommendation
3. Feed source wire through installed cord grip into light fixture junction area
a.
optional: slip source wire through cable holder provided to secure during installation
4. Connect source wires to terminal block [Fig.7] as described:
a.
strip SOURCE wires = .39"-.43" [10-11 mm] ___ 12-20 AWG [4.0-0.5 mm
b. connect SOURCE GROUND wire to terminal block position marked with GROUND SYMBOL
c.
connect SOURCE NEUTRAL wire to terminal block position marked with
d. connect SOURCE LIVE wire to terminal block position marked with
_ to connect source wires, press down on the tabs on top of the terminal block [with tool] and hold
_ insert stripped source wire _ release tab _ the terminal should now have engaged the inserted wire
_ lightly tug on the inserted wire to ensure engagement has occurred
• if using 208VAC [two 120VAC phases] _ connect the phase 1 wire to "L1" input and the phase 2 wire to "N" input
• since only the "L1" input is internally fused, an external fuse may be connected to the "N" input if required.
5. Once source wires are secured and connected, restore proper power to light fixture and check for illumination
CAUTION
Do not look directly into light fixture once powered and lit. Use protective shaded eye wear when viewing
:
4. Replace access cover [Fig.5] ............................................................................................... recommended torque _ 13 in.lb [1.5 Nm]
Fig.5
* Dialight is not responsible for selection of cord grip used on the installed light fixture
- Dialight only suggests that the cord grip selected to be used on the installed light fixture conforms to agency specifications required
1501 Route 34 South, Farmingdale, NJ 07727
Dialig
ht de México S.R.L de C.V. Calle Lirios s/n Col. Carlos Pacheco, Ensenada Baja California, México C.P. 22830
FLOODLIGHT - "FL" SERIES
INSTALLATION INSTRUCTIONS
100-277 VAC / 347-480 VAC
(100-277VAC) "N"
(100-277VAC) "L1"
(347VAC) "L1"
(480VAC) LIVE1 = "L1"/ LIVE 2 = "L2"
Fig.6
Tel: 732.919.3119
Fax: 732.751.5778
Document # 9100127212299 Rev.H / 41757
2
]
Fig.7
www.dialight.com
+52 (646) 156-70-80
January 2017