SECTION 6 − MAINTENANCE & TROUBLESHOOTING

6-1. Routine Maintenance

n = Check
* To be done by Factory Authorized Service Agent
Every
3
~Coolant Filter, durning heavy
Months
service, clean more frequently.
Every
6
Months
nlHoses
Every
Change
12
Coolant (If
Months
Using 043 809
or 043 810
Coolant)
ZReplace coolant.

6-2. Coolant Maintenance

1

6-3. Troubleshooting

Trouble
Coolant system does not work.
Decreased or no coolant flow.
Z = Change
~ = Clean
nl Labels
Be sure input power cord is plugged in to energized receptacle.
Check line fuses or circuit breaker, and fuses F1, F2 if applicable, and replace or reset if necessary.
Motor overheated. Unit starts running when motor has cooled.
Have Factory Authorized Service Agent check Power switch S1 and motor (Mot).
Add coolant.
Check for clogged hoses or coolant filter. Clean filter or clean / replace hoses if necessary.
Disconnect pump, and check for sheared coupling. Replace coupling if necessary.
= Repair
~ Blow out heat exchanger fins.
nCheck coolant level. Top off with
distilled or deionized water if necessary.
Change
Coolant (If
Using Water)
ZReplace coolant.
Tools Needed:
3/8 in.
801 189-C / 803 557-A
Remedy
!
Disconnect power
before maintaining.
l = Replace
1
Coolant Filter
Unscrew housing to clean filter.
Changing coolant: Drain coolant by
tipping unit forward. Fill with clean
water and run for 10 minutes. Drain
and refill.
.
If replacing hoses, use hoses
compatible with ethylene gly-
col, such as Buna-n, Neo-
prene, or Hypalon. Oxy-acety-
lene hoses are not compatible
with any product containing
ethylene glycol.
OM-248 626 Page 9