5-7. Connecting Remote Control

5-8. Electrical Service Guide

Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommenda-
tions are for a dedicated circuit sized for the rated output and duty cycle of the welding power source.
In dedicated circuit installations, the National Electrical Code (NEC) allows the receptacle or conductor rating to be less than the rating
of the circuit protection device. All components of the circuit must be physically compatible. See NEC articles 210.21, 630.11, and
630.12.
50/60 Hertz Models
Input Voltage (V)
Input Amperes (A) At Rated Output
Max Recommended Standard Fuse Rating In Amperes
Min Input Conductor Size In AWG
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG
Reference: 2011 National Electrical Code (NEC) (including article 630)
1 If a circuit breaker is used in place of a fuse, choose a circuit breaker with time-current curves comparable to the recommended fuse.
2 "Time-Delay" fuses are UL class "RK5" . See UL 248.
3 "Normal Operating" (general purpose - no intentional delay) fuses are UL class "K5" (up to and including 60 amps), and UL class "H" ( 65 amps and
above).
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table
310.15(B)(16). If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable
requirements.
A
K
B
C L N
M
D
E
OR
1
2
Time-Delay Fuses
Normal Operating Fuses 3
4
4
.
A complete Parts List is available at www.MillerWelds.com
1
J
I
H
G
F
OR
230
380
400
57
34
33
70
40
40
90
50
50
6
8
8
145 (44)
256 (78)
284 (86)
8
10
10
!
Turn off power before con-
necting to Remote 14 recep-
tacle.
1
Remote 14 Receptacle RC14
Connect remote control to RC14.
Ref. 800 166-D / Ref. S-0004-A / S-0750
440
460
575
30
29
23
35
35
25
45
40
35
10
10
10
226 (69)
243 (74)
380 (116)
10
10
10
OM-2252 Page 19