ABB DODGE PARA-FLEX Manual - Página 4

Navegue en línea o descargue pdf Manual para Equipamiento industrial ABB DODGE PARA-FLEX. ABB DODGE PARA-FLEX 4 páginas. Couplings includes atex approved couplings

In hazardous environments, DODGE elastomeric couplings
should not be considered as fail safe or "break-away" power
transmission devices. Overloads imposed to these devices
could cause irreparable damage, shall be considered an
explosive hazard, could create projectiles, and/or could cause
torque transmission interruptions. The coupling shall be
sized and used to the stated torque capabilities of the unit as
published in the DODGE PT Components Engineering Catalog.
Any assistance needed in selection shall be referred to an ABB
representative.
Additional Instruction for Safe Installation and Use
1.
All rotating parts should be guarded to prevent contact with
foreign objects which could result in sparks, ignition, or
damage to the coupling.
2.
Couplings should be periodically inspected for normal
wear, dust/dirt buildup or any similar scenario that would
impede heat dissipation.
3.
Increasing levels of vibration and noise could indicate the
need for inspection, repair or replacement of the coupling
or element.
ABB Motors and Mechanical Inc.
5711 R. S. Boreham Jr. Street
Fort Smith, AR 72901
Ph: 1.479.646.4711
Mechanical Power Transmission Support
Ph: 1.864.297.4800
new.abb.com/mechanical-power-transmission
baldor.com
© ABB Motors and Mechanical Inc.
MN4027
(Replaces 499710)
EU Declaration of Conformity
The undersigned, representing the following supplier and the following authorized representative-
Baldor Electric Company
5711 R. S. Boreham, Jr. Street
Fort Smith, Arkansas 72901 USA
This declaration is issued under the sole responsiblity of the manufacturer.
herewith declare that the Products
Couplings
Dodge Paraflex, Dodge D-Flex Equipment Group I, Category M2
Product identification (brand and
catalogue number/part number):
c / Equipment Group II Category 2 GD c T5 T amb - 30°C to
+50°C
are in conformity with the provisions of the following EC Directive(s) when installed in accordance with the installation
instructions contained in the product documentation:
2014/34/EU
ATEX
and that the standards and/or technical specifications referenced below have been applied:
EN 13463-1:2009
Non - Electrical Equipment For Potentially Explosive Atmospheres -Method And
Requirements
EN 13463-5:2011
Non - Electrical Equipment For Potentially Explosive Atmospheres – Part 5
Protection by constructional safety 'c'
Notified Body:
Sira Certification Services Ltd
Unit 6
Hawarden Industrial Park
Hawarden
DEESIDE
CH5 3US
Certificate: SIRA 04ATEX9358
Supplier:
Signature
Name:
L. Evans Massey
Position:
Manager Standards and Certification
Date:
15 January 2018 Greenville, SC USA
Document Control Number: DOC-BEZ-DA-M22-E-EN.DOC
4.
Electrical sparks are a source of ignition. To reduce the risk,
proper electrical bonding and grounding is recommended.
5.
Overloading may result in breakage or damage to the
coupling or other equipment. As a result the coupling
could become an explosion hazard. Damaged coupling
components or elements must not be operated in
hazardous environment.
6.
If thrust loading or axial movement is anticipated, The
DODGE PARA-FLEX coupling is the desired unit for use
as it has design capability of accepting this movement up
to 5/16". Couplings are not intended to be used as thrust
bearing members.
7.
Coupling guards should have a minimum of 2" clearance
over PARA-FLEX tire style couplings. (3" clearance
for PARA-FLEX style couplings greater than 16" outer
diameter.)
8. The date code should be read as:
ABB Automation Products GmbH
Oberhausener Straße 33
40472 Ratingen, Germany
Authorised Representative:
Signature
Name:
Michael Klein
Position:
Regional Sales and Marketing Manager Central
Europe
Date:
15 January 2018 Ratingen, Germany
Indicates Month
14
1 / 1
*4027-0419*
All Rights Reserved. Printed in USA.
04/19 Litho 20,000
(one dot per
month)
Indicates
Year