6-5.

Sequence Of Cutting Operation

1
3
5
7
A complete Parts List is available at www.MillerWelds.com
Complete Parts List is available at www.MillerWelds.com
2
90
4
6
Ref. 254087-A
The pilot arc starts immediately
when trigger is pressed.
Step 1. Connect work clamp to a clean,
paint-free location on workpiece, as close to
cutting area as possible.
Step 2. For standard (shielded) cutting,
place drag shield on edge of metal. For ex-
tended (non-shielded) cutting, use 1/8 in.
(3.2 mm) standoff distance (dragging tip will
reduce tip life).
Step 3. Raise trigger lock and press trigger.
Pilot arc starts.
Step 4. After cutting arc starts, slowly start
moving torch across metal.
Step 5. Adjust torch speed so sparks go
through metal and out bottom of cut.
Step 6. Pause briefly at end of cut before re-
leasing trigger.
Step 7. Postflow continues for approximately
20 seconds after releasing trigger; cutting
arc can be instantly restarted during postflow
by raising trigger lock and pressing trigger.