Diametral VirBuster 20000 A Manual - Página 8
Navegue en línea o descargue pdf Manual para Limpiador de aire Diametral VirBuster 20000 A. Diametral VirBuster 20000 A 12 páginas.
VirBuster
WARNING
Do not disinfect the room longer than recommended. With long-term exposure to
ozone, in the order of hours, ozone can damage objects in the disinfected room!
Recommendations before starting disinfection
Thorough mechanical cleaning should first take place before disinfecting the premises.
Thoroughly vacuum and wipe the floors, remove any deposits and deposits of dust or
other dirt.
For best results when disinfecting, clean surfaces that come into contact with humans
with suitable products beforehand.
Recommended times and performances
Model
Space
Car interior
50m3 / 20m2
100m3 40m2
125m3 / 50m2
250m3 / 100m2
500m3 / 200m2
750m3 / 300m2
P = use several devices, derive time according to the power of the device (s) and the times
related to the size of the space 100m3. N = not recommended. Square meters are calculated
at a ceiling height of 2.5 m.
The times can be increased by 20% as required without the risk of damaging the device.
Fuse replacement
Before replacing the fuse, first disconnect the power supply by unplugging the
power cord from the outlet and the power connector (10) in exactly that order.
Use a screwdriver to slide out the instrument fuse holder (10) and remove the fuse.
In its place, insert a new fuse corresponding to the data on the nameplate of the
device.
Slide the instrument fuse holder back into the fused power connector (10).
Plug the power cord into the fused power connector (10).
Check that the main switch (1) is in position 0 and connect the mains plug to the
mains. This completes the fuse replacement.
8
VirBuster 4000
VirBuster 8000
30
40
80
90
P
N
N
VirBuster 10000 VirBuster 20000
20
15
20
15
40
25
45
30
90
60
P
120
N
P
15
10
12
15
30
60
90