Miller XMT 304 Manual del usuario - Página 26

Navegue en línea o descargue pdf Manual del usuario para Sistema de soldadura Miller XMT 304. Miller XMT 304 40 páginas. 4-rack and 6-rack
También para Miller XMT 304: Manual del usuario (26 páginas), Manual del usuario (37 páginas)

Miller XMT 304 Manual del usuario

6-1. Front Panel Controls

1
Power Switch
.
The fan motor is thermostatically
controlled and only runs when cooling is
needed.
2
Voltmeter (see Section 6-2)
3
Ammeter (see Section 6-2)
4
V/A (Voltage/Amperage) Adjustment
Control
5
Mode Switch
The Mode switch setting determines both the
process and output On/Off control (see Sec-
tion 6-3). Source of control (panel or remote)
for the amount of output is selected on the V/A
Control switch.
For Air Carbon Arc (CAC-A) cutting and goug-
OM-2208 Page 22
SECTION 6 − OPERATION
1
2
7
ing, place switch in Stick position. For best re-
sults, place Inductance/Dig control in the
maximum position.
6
V/A (Voltage/Amperage) Control Switch
For front panel control, place switch in Panel
position and use the V/A Adjust control.
For remote control, make connections to Re-
mote 14 receptacle, and place switch in Re-
mote position. In most modes, remote control
is a percent of V/A Adjust control setting (val-
ue selected on V/A Adjust is maximum avail-
able on remote). In the MIG mode, remote
control provides full range of unit output re-
gardless of V/A Adjust control setting
7
Inductance/Dig Control
Control adjusts Dig when Stick or CC mode is
selected on mode switch. When set towards
3
5
minimum, short-circuit amperage at low arc
voltage is the same as normal welding
amperage.
When set towards maximum, short-circuit
amperage is increased at low arc voltage to
assist with arc starts as well as reduce stick-
ing while welding (see volt-ampere curves in
Section 4-6).
Select setting best suited for application.
Control adjusts inductance when MIG or
V-Sense Feeder position is selected on the
mode switch. Inductance determines the
"wetness" of the weld puddle. When set to-
wards maximum, "wetness" (puddle fluidity)
increases.
When Pulsed MIG or one of the TIG modes is
selected, this control is not functional.
4
6
Ref. ST-175 086