5-5. Water-Cooled Gun Connections

8
9
Tools Needed:
9/16 in
Left Side
10
11
4
7
1
2
6
.
Turn on coolant supply before
welding or gun will be dam-
aged.
1
Gun Control Cable
Insert plug into Gun Control
receptacle, and tighten threaded
collar.
2
Gun Power Pin
3
Gun Securing Knob
4
Gun Bushing
5
Drive Casting
4
3
Loosen gun securing knob, and
insert gun power pin through gun
bushing until it bottoms against
drive casting. Tighten knob. Close
and latch door.
6
Gun (Coolant) "In" Hose
5
Connect to Water "In" fitting on
feeder (left-hand threads).
7
Gun (Coolant) "Out" Hose
Connect to Water "Out" fitting on
feeder (left-hand threads)
8
Water Cooler Output
9
Water Cooler Input
10 Feeder (Coolant) Output
11 Feeder (Coolant) Input
Ref. 242 439-A / 805 353-A / 805 351-A / 805 106-A