Miller Axcess 675 Manual del usuario - Página 19

Navegue en línea o descargue pdf Manual del usuario para Accesorios de soldadura Miller Axcess 675. Miller Axcess 675 48 páginas. Automatic welding interface and arc welding power source
También para Miller Axcess 675: Manual del usuario (48 páginas)

4-6. Network Wire Feeder Receptacle Functions

9
F
E
G
D
I
H
C
A
B
*The remaining pins are not used.

4-7. Electrical Service Guide

Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These
recommendations are for a dedicated circuit sized for the rated output and duty cycle of the welding power source.
In dedicated circuit installations, the National Electrical Code (NEC) allows the receptacle or conductor rating to be less than the rating
of the circuit protection device. All components of the circuit must be physically compatible. See NEC articles 210.21, 630.11, and
630.12.
NOTICE − INCORRECT INPUT POWER can damage this welding power source. This welding power source requires a CONTINUOUS supply of
input power at rated frequency(+10%) and voltage (+10%). Phase to ground voltage shall not exceed +10% of rated input voltage. Do not use a genera-
tor with automatic idle device (that idles engine when no load is sensed) to supply input power to this welding power source.
.
Actual input voltage should not exceed  10% of indicated required input voltage. If actual input voltage is outside of this range, output may not
be available.
Input Voltage (V)
Input Amperes (A) At Rated Output
Max Recommended Standard Fuse Rating In Amperes
Min Input Conductor Size In AWG
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG
Reference: 2011 National Electrical Code (NEC) (including article 630)
1 If a circuit breaker is used in place of a fuse, choose a circuit breaker with time-current curves comparable to the recommended fuse.
2 "Time-Delay" fuses are UL class "RK5" . See UL 248.
3 "Normal Operating" (general purpose - no intentional delay) fuses are UL class "K5" (up to and including 60 amps), and UL class "H" ( 65 amps and
above).
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table
310.15(B)(16). If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable
requirements.
Pin*
Ref. 803 823-A
1
2
Time-Delay Fuses
3
Normal Operating Fuses
4
4
A
Not used.
B
Shield.
C
Volt sense.
D
Can low.
E
Can high.
F
+24 volts DC common.
G
+ 24 volts DC
H
Motor voltage −40 volts
I
Motor voltage +40 volts
Pin Information
Elec Serv 2011−08
60 Hz Three Phase
230
400
460
89
50
44
110
60
50
125
80
70
3
6
8
173
275
231
(53)
(84)
(70)
6
8
8
OM-217 751 Page 15
575
35
40
50
8
361
(110)
10