3-4. Symbols And Definitions

.
Some symbols are found only on CE products.
Output
X
Duty Cycle
Input
Constant Current
Trigger Hold Off
Read Instructions
I
Primary Current
1

4-1. Specifications

Welding
Type of
Power
Input
Source
Power
Type
Constant
Voltage (CV)
24 Volts AC
Single Phase
DC With
10 Amperes
14-Pin And
Contactor
50/60 Hz
Control

4-2. 14-Pin Plug Information

J
A
K
I
B
L
H
N
C
M
G
D
F
E
*The remaining pins are not used.
Input
Wire Feed
Cold Jog (Inch) To-
wards Workpiece
Circuit Breaker
Trigger Hold On
U
Primary Voltage
1
SECTION 4 − INSTALLATION
Wire Feed
Wire
Speed
Diameter
Range
Range
50 to 700 ipm
.023 To 5/64 in
(1.3 To 17.8
(0.6 To 2 mm)
mpm)
Pin*
A
24 volts AC with respect to socket G.
B
Contact closure to A completes 24 volts AC contactor control circuit.
G
Circuit common for 24 volts AC circuit.
C
+10 volts DC input from power source to wire feeder with respect to socket D.
D
Remote control circuit common.
E
0 to +10 volts DC output signal from wire feeder to power source with respect to socket D.
H
Voltage feedback; 0 to +10 volts DC, 1 volt per 10 arc volts.
F
Current feedback; 0 to +10 volts DC, 1 volt per 100 amperes.
A
Amperes
Percent
Purge By Gas
Constant Voltage
I
Rated Welding
2
Current
U
Conventional Load
Voltage
2
Input
Max. Wire
Welding
IP
Spool
Circuit
Rating
Capacity
Rating
100 Volts,
45 lb
500
(20.4 kg),
Amperes,
23
12 in
100%
(304 mm)
Duty Cycle
Pin Information
V
Volts
IP
Degree Of Protec-
tion
Fast
Slow
Increase
Hz
Hertz
Overall
Weight
Dimensions
Length: 21 in
(533 mm)
Width: 9 in
25.5 lb
(229 mm)
(11.6 kg)
Height: 15-1/2 in
(394 mm)
OM-1500-15 Page 13