Chromalox Chroma-FP2 Manual de instalación y funcionamiento - Página 8
Navegue en línea o descargue pdf Manual de instalación y funcionamiento para Controlador Chromalox Chroma-FP2. Chromalox Chroma-FP2 13 páginas.
Technician Settings (Cont.)
Parameters:
P01 - Temperature set point
1. Move DIP switch S1 located on the side of
thermostat to ON position.
2. "P01" and the temperature set point will
appear on display.
3. Use the [+] and [-] buttons to adjust the
temperature set point.
Range: 5...60°F / -15...+15°C,
Default: 37°F / 3°C
As long as the ambient temperature is lower
than the temperature set point P01, the
Chroma-FP will turn ON.
P02 - Lower limit temperature for heating
1. Press the [SELECT] and [+] buttons
simultaneously.
2. "P02" and the low limit temperature will
appear on display.
When the temperature on the temperature
sensor drops below the low temperature
limit, the heating system will stop.
3. Use the [+] and [-] buttons to adjust the
temperature set point.
Range: -40...+23°F / -40...-5°C
Default: -40°F / -40°C
4. Press the [SELECT] and [+] buttons
simultaneously again.
5. The word "ON" or "OFF" will appear on display.
6. Use the [+] and [-] buttons enable (ON)
Low limit
or disable (OFF) the P02 parameter.
Temperature
If disabled, the heating system will operate
without low temperature limitations.
Temperature
set point
P02
Low limit
Temperature
enabled
P02
P02
enabled
disabled
14
P03 – Time delay before stopping the heater
1. Press the [SELECT] and [+] buttons
simultaneously.
2. "P03", "dL" and the time delay before
stopping the heater (Hold ON) will appear
on display. The hours will blink.
3. Use the [+] and [-] buttons to adjust the hours
of the time delay.
Range: 0000...9999 minutes Default: 120 minutes
Note 1. The time delay countdown will start
when the ambient temperatures rises above the
set point temperature.
P04 - Manual mode ON time
1. Press the [SELECT] and [+] buttons
simultaneously.
2. "P04", "On" and the time "Manual ON" mode
time period will appear on display. The hours
will blink.
3. The delay time parameter defines a time
frame in which the heater remains ON after
receiving an "Manual ON" command.
4. Use the [+] and [-] buttons to adjust the hours
of the working time.
P02
Range: 00...99 hours Default: 03 hours
disabled
5. Press the [SELECT] and [+] buttons
simultaneously again. The minutes will blink.
6. Use the [+] and [-] buttons to adjust the
minutes of the working time.
Range: 00...59 minutes Default: 00 minutes
P05 -Not in Use
1. Press the [SELECT] and [+] buttons
simultaneously.
2. "P05" will appear on display.
3. Proceed to P06.
Time delay
(minutes)
Manual ON
(minutes)
15