VERY IMPORTANT: Always read the safety and operations instructions before starting up
the appliance to obtain full safety and operating instructions.
Operation of the equipament is totally controlled by a digital DIXEL thermostat, which allows for
selection of temperature.
Connect the equipment to the mains. If "OFF" appears in the digital display, press ON/OFF key.
It is necessary to wait +/- 2 minutes for the compressor to star after the cabinet is connected to the
mains.
Digital controls the temperature from -2ºC to +8ºC on SNACK models (ID 40-R6), 0ºC to +5ºC
(IDS40-R6) on FISH models and negative models (IE40-R2) from -15ºC to -22ºC with factory set
point -18ºC.
Not USED
SET1=SET 2
SET
To change the set point, you shall do the steps described bellow:
To do this press SET key more than 2 seconds to change the set point value;
The value of set point will be displayed and the "ºC" will star blinking;
To change the Set value push UP or DOWN arrows within 10 seconds;
To record the new set point value, push the SET key again or wait for 10 seconds
Defrosting is automatic and controlled by the thermostat, the water from the process is drained
through a hole into a container. This container must be empty
regulary, -/+ twice a week.
When is possible connect to the sewers with a siphon where
the equipment is installed.
Very Important:
This recipient (water tray) is supplied
inside the cabinet. The user must introduce it on the
guides below the cabinet, and make sure the sewage pipe
send the water to inside the water tray. See the scheme:
QUICK START GUIDE
ALARM SIGNALS
Message
"P1"
"P2"
"P3"
"HÁ"
Maximum temperature alarm
"LA"
Minimum temperature alarm
"dA"
"EA"
"CA"
Serious external alarm (i2F=bAL)
"CA"
Pressure switch alarm (i2F= PAL)
"rtc"
Real time clock boar failure
rtF
Cause
Room probe failure
Evaporator probe failure
Third probe failure
Door open
External alarm
Real time clock alarm
UP
DOWN// +3 seg Defrost ON
ON/ OFF
EN