5. RO installation, Сont.
Connection of JG tubes
Pull the locking clip (2) off the plastic plug (1). Then install the previously wetted end of the tube (3) into the
fitting piece approx.15 mm up to the stop. Next, put the locking clip (2) back.
Make sure that the tube (3) is tightened correctly: the tube should not be pulled out by force greater than
8-10 kgf.
Disconnection of JG tubes
Pull the locking clip (2) off the plastic plug (1), then pull the tube (3) out by applying pressure on the face
of the connecting piece. To apply pressure, use the tube disconnection key (4) included in the water filter set.
3
10
3
1
Figure 6. Connection of JG tubes
2
Figure 7. Disconnection of JG tubes