8. Slotted plug installation

Figure 10. Slotted plug installation
Slotted plug
1. Install the slotted plug into the JG tube
3/8" (9.5 mm) tube to a stop, as shown
on figure 10.
2. Remove the clip from the JG tube 3/8" socket
of the water filter, and then connect this tube
end to it (see the connection of the JG tubes
on figures 6 and 7).
ATTENTION!
The set includes three slotted
plugs: one for installation and two are for
spares.

9. Starting RO

To start RO, you must connect the supply tube
and carry out the flushing procedure of filter
and membrane cartridges.
Step 1
Connect the incoming tubes according to the
diagram below (figure 11). The tube connection
scheme is illustrated on figure 6
Figure 11. Incoming tubes connection
IN
10
OUT
DRAIN
Step 2
Preparing RO for operation
• Rotate the three latches 90 degrees in a coun-
terclockwise direction and remove the water
filter cap (figure 2).
Table 2. Positions of RO cartridges
in preparation for operation
Stop button colors
BLACK
BLUE
RED
WHITE
• Make sure the service cap is installed in the
housing.
• Remove the shrink film from the cartridges.
• Rinse the sealing O-Rings of the cartridges
and service cap.
• Remove service caps and install cartridgies
according to table 2. For convenience, the
stop buttons of the collectors have the dif-
ferent color.
• Set the shutoff valve on the connection node
into the open position, as shown on figure 4.
• Leave the clean water faucet open for
10 minutes.
The noise during the flushing of the cartridges
is not a defect.
• Close the clean water faucet.
Step 3
Flushing the membrane cartridge unit
• Set the shutoff valve on the connection node
into the closed position, as shown on figure 5.
• Remove the service plug and install membrane
cartridge.
• Interchange the К5 / К1 and K2 cartridges.
• Turn the shutoff valve on the connection node
into the open position.
• Open the clean water faucet, then wait for the
water to start flowing.
Cartridge type
K2
К5 / К1
Service Cap
К7М / К7ВМ