Service life (operating time) of replaceable filtering cartridges:
Name
K1 replaceable filter cartridge:
RO-100S replaceable membrane cartridge:
K7M replaceable filter cartridge:
The data are based on the consumption of 10–12 litres of drinking water per day by a family of 3–4 people.
The service life (operating time) of the water pre-treatment cartridge may vary depending on
*
the amount of impurities in the source water. The service life (operating time) of the cartridges is
indicated for water that meets sanitary standards. K1 replaceable filter cartridge must be changed
The service life of the RO-100S membranes cartridge directly depends on the performance of
**
the pre-treatment cartridges. Please, replace exhausted filter cartridges in a timely manner. every
1–3 months if water entering your RO-312S Pro does not meet sanitary standards (with a high content
of mechanical impurities).
The RO-312S Pro shelf life (with a set of replace-
able filter cartridges) is 3 years before operation
when stored at + 5 to + 40 ºС, without breach
of packaging.
Fault table
Fault
Storage tank is filling
slowly or not at all
The storage tank is full, but
water continues to flow into
the drain
There is no water in the drain
If you have any issue with the operation of your
RO-312S Pro, please, contact the seller or the
manufacturer.
Cause
Block cartridge is clogged
pretreatment
Clogged membrane cartridge
Defective diaphragm valve
Connection unit tap closed
Low inlet pressure
Foreign object in one
of the supply tubes
Auto valve defective
Cartridges of the pretreatment
unit clogged
Clogged membrane cartridge
Restrictor clogged
(drainage restriction)
Service life (operating time)
up to 6 months*
1.5–2 years**
1 year
Remedy
Replacing the cartridge
pre-treatment unit
Replacing a Membrane Cartridge
Contact customer service
Open the tap on the connection unit
Installation of a boost pump for the en-
tire apartment or separately on the filter
Contact customer service
Contact customer service
Replacing the cartridges
of the pre-treatment unit
Replacing a Membrane Cartridge
Contact customer service