AQUABEAM/GROBEAM 500 PARTS LlST/DIMENSIONS
I. Power supply unit (PSU) - with single or twin DC outlets.
2. Mains power supply cord with UK, European or USA plug
configuration.
3.
AquaBeam/GroBeam 500 lamp unit - double or single lamp units with 3m
(10ft) cable complete with matching plug connector to the DC outlet from
the PSu.
4. Batten fixing bracket - one supplied per lamp unit.
5. Fixing kit (not shown).
.""""''-----
- -
.-
--
490mm
-----------;~.
35mm[:~t~
..
;
~-~~:~~~~ ~;~@1
Depth
=
45mm
AQUABEAM/GROBEAM 1000 PARTS LlST/DIMENSIONS
I
~
4
2
~.
/ '
'''
:--.....
'
6
r
._
4
I
.
Power supply unit (PSU) - with twin DC
outlets.
2.
Mains power supply cord with
UK,
European or USA plug
configuration.
3.
AquaBeam/GroBeam 1000 lamp unit - with 3m (10ft) cable complete with
matching plug connectors to die DC outlets from the PSu.
4.
Fixing bracket - two supplied per lamp unit.
5. Fixing kit (not
shown).
6.
AquaRay PowerControl unit (only supplied with "AquaBeam/GroBeam 1000
PowerContro/" lamp
units).
1""""'
-
-
198 mm
~I
47.5 mm
~_-~~
- - - -
----
-
- ..:-:.,.
~
=;;::a~
Depth
=
198 mm
ASSEMBLY
AquaRay lamp units are fully assembled and ready to use.
INSTALLATION
Please
note:
These lamp units are NOT designed to be operated partially or
fully
submerged.
They must be SECURELY mounted not less than ISmm
from the maximum water level ofthe aquarium.
The versatile, compact and light-weight design allows the AquaRay lamp units
to be installed above your aquarium in a variety of ways to suit any application.
The design of the lamp units means they are able to be fitted in dose proximity
to
the sunace of the aquarium
. However,
mounting further from the surface of
the aquarium will maximise the spread of light from the AquaRay's unique wide
angled beam
I.
AQUABEAM/GROBEAM 500
A. Using an AquaBeam/GroBeam 500 batten fixture (supplied) for
more permanent attachment with three screws to the INSfDE or
UNDERSIDE of a wooden or metal hood or other enclosure.
Grub Screw
Grub Screw
Caution: To securely attach the fi xing batten to the wooden or metal hood or
other enclosure, all three screws must be
used.
Caution: Once the batten fixture has been attached
to
the wooden or metal
hood or other enclosure using all three screws, push-fit the lamp unit onto the
batten then tighten the two grub screws to secure the lamp unit to the batten
fixture
.
Please note: the
stainless
steel grub
screws
supplied with the batten and
suspension fixtures should be fulry tightened to secure the
AquaBeam/GroBeam 500 lamp unit to the
batten.
2
B.
Without any fixtures, by resting the AquaBeam/GroBeam 500 lamp
unit on the specially designed front lens face for installation ON
TOP of a transparent cover glass or plastic condensation
tray.
;t'
I
2. AQUABEAM/GROBEAM 1000
A. Using the AquaBeam/GroBeam 1000 brackets (supplied) for more
permanent attachment with six screws (stainless steel self tap, or
nylon nut and bolt - all supplied) to the INSIDE or UNDERSIDE
of a wooden or metal hood or other enclosure.
~l
Caution:
Before the brackets have been attached to the wooden or metal
hood or other enclosure using all six
screws,
make sure that they are fully
pushed OntO all of the AquaBeaml GroBeam 1000's heat sink
attachments.
Caution: To securely attach the bracket to the wooden or metal hood or
other
enclosure,
all six screws must be
used.
B. Without any fixtures, by resting the AquaBeam/GroBeam 1000
lamp unit on the specially designed front lens face for installation
ON TOP of a transparent cover glass or plastic condensation tray.
I i
r
Further mounting options are available. Please refer to the AquaRay Modular
Mounting System leaflet included with this unit. For other tips and answers to
some frequently asked questions visit:- www.tropicalmarinecentre.co.uk
and click on "Aquarium Products" - "Lighting" - "AquaRay FAQs".
OPERATION
Once mounted above the aquarium according to one of the recommended
installation methods detailed above, the lamp unit(s) may be connected to the
power supply unit (PSU) and then the PSU connected to the
mains
using the
power cord supplied, and switched on. The lamp unit must not be connected
to,
or used with, any PSU other than that supplied by Tropical Marine Centre.
The PSU may be connected to the mains via a suitable 24 hour timer device
(not supplied) to regulate when the lamp unit
is
switched on or
off.
The PSU
may also be connected to an AquaRay Control unit (supplied only with the
"AquaBeam/GroBeam 1000
PowerControl"
units, but al so ava ilable separately
please ask your local TMC Stockist) to simulate sunrise, sunset and
moonlight.
Caution: Do not attempt to control or regulate in any way the DC supply
from the PSU to the AquaRay lamp unit. Any attempt to do so may invafidate
the 5 year guarantee on your AquaRay lamp
unit.
MAINTENANCE
Caution: To avoid possible electric
shock,
special care should be taken when
using this electrical appliance near
water.
Caution: Always isolate the PSU from mains electricity before installing or
carrying out any maintenance to the AquaRay lamp unit.
Caution: Do not attempt to open the plastic case of the PSU. This will invalidate
the I year guarantee on the PSu.
Caution:
Do not attempt to open the plastic casing of your AquaRay lamp
unit. This will damage the waterproof sealing and invalidate the 5 year guarantee
on the lamp
unit.
An AquaRay lamp unit and associated power supply unit (PSU) are sealed units
and are not customer serviceable
parts.
The lamp array inside the lamp unit is
also not a
customer
serviceable part and the whole lamp unit is to be disposed of
at the end of its life (>50,000 hours).
An AquaRay lamp unit should need little or no maintenance once set
up.
However due to salt deposits and the high calcium level in marine aquariums it is
common for deposits to build up on the body of the unit.
Therefore it is recommended that:
a. The lens face of the AquaRay lamp unit is cleaned periodically with a warm,
damp cloth.
b. The heat sink on the rear of the unit is kept free of large particles of salt
and other films or deposits which might obstruct the free movement of air
around the vanes of the heat sink. Occasional cleaning with a small brush
and/or dry, lint-free cloth is recommended.