Aquarea PAW-TD 30 C1E5-UK Manual de instalación, mantenimiento y servicio - Página 5

Navegue en línea o descargue pdf Manual de instalación, mantenimiento y servicio para Calentador de agua Aquarea PAW-TD 30 C1E5-UK. Aquarea PAW-TD 30 C1E5-UK 8 páginas.

Aquarea PAW-TD 30 C1E5-UK Manual de instalación, mantenimiento y servicio

Technical Data

Specification
Storage volume - l.
Accessible volume of 40°C hot water - l.
Weight - kg.
Freight volume - m³
Diameter x height - mm.
Coil surface
Maximum inlet water pressure, vessel - bar
Maximum water pressure, coil - bar
Maximum operating temperature - °C
Corrosion protection
Pressure drop through primary heater - bar
Primary flow rate - l.
Disassembly, recycling and disposal
Disassembly
1. Disconnect power supply to the product
2. Turn off water supply
3. Drain product of water - see 'Draining' on page 3
4. Disconnect all pipe fittings to product. The product can now be removed.
Recycling and disposal
This product is fully recyclable and should be disposed of in accordance with local recycling rules and practices.
Subject to changes without notice
PAW-TD 20 C1E5-UK
PAW-TD 30 C1E5-UK
194
47
0,46
ø595 x 1270
ø595 x 1750
1,8 m²
6
9
98
Citric acid treatment Citric acid treatment
284
57
0,62
1,8 m²
6
9
98
5