AquaScape 70 GPH Instrucciones de instalación

Navegue en línea o descargue pdf Instrucciones de instalación para Bomba de agua AquaScape 70 GPH. AquaScape 70 GPH 2 páginas. Statuary water pump
También para AquaScape 70 GPH: Manual de instrucciones y mantenimiento (2 páginas)

AquaScape 70 GPH Instrucciones de instalación
I N S T A L L A T I O N
STATUARY WATER PUMP
70 GPH Water Pump
180 GPH Water Pump
Item #91023
Item #91025
90 GPH Water Pump
320 GPH Water Pump
Item #91024
Item #91026
Contents
No.
Description
No.
1.
1/4" Stepped Plastic Adapter
5.
2.
1/2" Cylinder Plastic Adapter
6.
3.
5/8" Straight Adapter Tube
7.
4.
5/8" Bent Adapter Tube
8.
1
2
6
5
8
70 GPH
7
2
5
6
8
180 GPH
7
Safety Information
WARNING: Risk of electric shock – This pump has not been approved for use in
swimming pool or marine areas
WARNING: To provide continued protection against risk of electric shock, connect to
properly grounded, ground fault circuit interrupter (GFCI) outlets only, using the following
guidelines:
(A) Have a qualified electrician install a properly grounded receptacle outlet, acceptable for outdoor
use and protected from snow and rain.
(B) Inspect cord before using.
(C) Do not use an extension cord.
(D) Any wiring of pumps should be performed by a qualified electrician to ensure code compliance
and user safety.
(E) Unplug pump at receptacle outlet when not in use or before removal from pond.
(F) To reduce risk of electrical shock, all wiring and junction connections should be made per local
codes. Requirements may vary depending on usage and location.
(G) The power cable should be protected at all times to avoid punctures, cuts, bruises and
abrasions.
(H) Never handle power cords with wet hands.
(I) Do not remove cord and strain relief. Do not connect conduit to pump.
(J) Do not use power cable to lift pump.
• Always operate the pump fully submerged; or if using in-line ensure a constant source of fresh
water. Failure to do so may overheat the pump and cause it to fail, voiding the warranty.
• Use only in fully assembled state, paying particular attention to ensure that both the outer and inner
filter screens are attached to the pump. Failure to operate the pump without the filter screen will
allow large debris to enter the pump and cause the pump to fail, voiding the warranty.
• Do not wear loose clothing that may become entangled in the impeller or other moving parts.
• Keep clear of suction and discharge openings. DO NOT insert fingers into pump with power
connected.
• Do not pump hazardous materials or liquids, such as oil, saltwater or organic solvents.
• Do not block or restrict discharge.
• Products returned must be cleaned, sanitized, or decontaminated, as necessary, prior to shipment
to ensure that employees will not be exposed to health hazards in handling said material. All
applicable laws and regulations shall apply.
IMPORTANT: Aquascape, Inc. is not responsible for losses, injury, or death resulting from
a failure to observe these safety precautions, misuse or abuse of pumps or equipment.
Description
Flow Controller
Impeller
Impeller Cover
Intake Screen
2
1
6
90 GPH
7
3
4
6
320 GPH
7
facebook.com/aquascapeinc
youtube.com/aquascape4
pinterest.com/aquascapeinc
instagram.com/aquascape_inc
I N S T R U C T I O N S
Statuary Water Pump Specifications
• Input Voltage: 120V AC
• Input Frequency: 60 Hz
• Submersible pump
• For outdoor or indoor use
Model
Max Flow Rate GPH/LPH
Max Head Height
Motor Type
Wattage
Amperage
Power Cord Length
Discharge Hose Diameter
Installation
This pump is designed to be operated fully submerged in the
water feature (Ex. 1).
1. Select the appropriate fitting(s) needed for your
application.
2. Attach tubing to the fitting (Ex. 2).
3. Connect the other end of the tubing to the fountain,
ornamental spitter, or filter.
• Connect the pump to an outlet that is protected by a ground
fault interrupter (Ex. 3). Once the pump is running and water
circulating through the filter(s) or waterfalls, check for any
fitting or waterfall leaks
8
where the external
connections are made.
5
General Maintenance
• Inlet Screen Cleaning
8
– If you notice diminished water flow, check inlet screen and
clean as needed (Ex. 4). Disconnect pump, remove from
water and clean debris from pump cover.
• Internal Pump Cleaning
– If you still have diminished flow rates, remove the impeller
cover to inspect the impeller rotor assembly (Ex. 5).
– If your rotor assembly impeller and internal pump body
have excessive scale build-up, clean with a mild acid, such
as white vinegar or non-abrasive calcium, lime, and rust
remover product
using a sponge or
soft-bristled brush
that won't scratch
impeller (Ex. 6).
Removing scale build
up will allow your
pump to run like new
again.
• Replacing the Impeller
Assembly
– The impeller assembly
is the only moving
part on the pump and will experience wear and tear. If you've cleaned the pump, as described
above, and still experience poor pump performance, it is most likely time to replace the impeller.
Replacing the impeller is extremely easy. Replacement Impeller Kits are available through your
local Aquascape dealer.
Winter Application
• The pump can be run during freezing weather, if desired, but should be removed if shutting down
the pump for the winter. Disconnect the tubing from the discharge fitting and remove the pump
from the pond. Clean the pump and inlet screens with fresh water and store the pump in a frost-
free location.
Troubleshooting
• Reduced Water Flow
– Pump or plumbing may be clogged. It may be necessary to clean the pump intake screen and
impeller.
• Pump Hums and Doesn't Push Water
– Pump or plumbing may be clogged. It may be necessary to clean the pump intake screen and
impeller.
– Remove the intake screen and impeller cover and inspect and clean the impeller rotor assembly
and internal pump body.
– Make sure nothing is blocking or wrapped around the impeller.
– Make sure the pump is receiving the correct voltage.
• Pump Not Working
– The ground-fault circuit-interrupter (GFCI) may have tripped.
– The pump is not receiving the correct voltage.
For more information about our company or products, please visit our website at
aquascapeinc.com or call us at US (866) 877-6637 CAN (866) 766-3426
©2022 Aquascape, Inc. • All Worldwide Rights Reserved
• Thermally protected
• This pump has been evaluated for use with
freshwater only
• Input amps and wattage - see chart below
Statuary Water Pump Specs
70 GPH
90 GPH
180 GPH
70/250
90/300
180/650
2'
3'
4'
Mag-drive
3.0
4.3
9.3
0.037
0.061
0.175
6'
1/2", 5/8"
Ex. 2
Ex. 5
320 GPH
320/1,200
5.5'
17.6
0.339
Ex. 1
Ex. 3
Ex. 4
Ex. 6
12/14/22