∙ Follow maintenance procedures to clean the intake and
water chamber cover
∙ Follow maintenance procedures to clean the impeller
and internal pump body
– Make sure the pump is receiving the correct voltage
– Make sure the impeller blades are not worn or damaged
• Pump not working
– Check Aquascape Smart Control App to ensure the
pump is set to run
– Ground fault circuit interrupter (GFCI) may have tripped
– The pump is not receiving the correct voltage
• Device won't pair
– Make sure the outlet is receiving power
– Make sure the network name and password are typed
in correctly
– Make sure you have adequate wireless coverage to
connect the device
– Reset the device to factory defaults
– Make sure the ground fault circuit interrupter (GFCI) is
not tripped
• Receiver displays an E1 message
– This means the input voltage going to the receiver is
greater than 142 volts. Have an electrician inspect the
outlet you have the receiver plugged into
• Receiver displays an E2 message
– Receiver is overheating - make sure the receiver is in a
shady or cooler area away from direct, intense sunlight
Warranty Information
Aquascape warrants that the SLD Adjustable Flow Pump will be free of manufacturing defects for three years from
date of purchase. Proof of purchase required. Warranty does not cover damage resulting from electrical supply
problems, improper wiring, lightning, negligent handling, misapplication, misuse, or lack of reasonable maintenance or
care. Warranty does not cover parts subject to normal wear, such as impellers. This product should only be operated
in fresh water, completely submerged, without corrosive chemicals like chlorine or bromine. If upon Aquascape's
inspection, the pump shows evidence of a manufacturing defect, Aquascape's liability is limited, at Aquascape's option,
to the repair of the defect, replacement of the defective product, or refund of the original purchase price. The warranty
excludes costs of labor, removal of product, shipping and expenses related to the installation and re-installation of the
product. All products that include plumbing (tubing, pumps, check valves) need to be properly drained and winterized
otherwise warranty is null and void. No liability for loss or damage of any nature or kind, whether arising out of or from
the use of the product, whether defective or not defective, is assumed by Aquascape, Inc. or its affiliates. Aquascape
shall not be liable for any incidental, consequential or other damages arising under any theory of law whatsoever.
45036-45037-45046 • 05/21
6
3 YEAR WARRANTY
For more information about our company or products, please visit our website at aquascapeinc.com
or call us at US (866) 877-6637 CAN (866) 766-3426
©2021 Aquascape, Inc. • All Worldwide Rights Reserved
Replacement Parts
SLD 2000-5000 Replacement Parts
No. Description
1.
45047 – SLD 2000-5000 Replacement Impeller with Gasket
2.
45042 – SLD Water Chamber Cover
SLD 4000-7000 Replacement Parts
No. Description
1.
45044 – SLD 4000-7000 Replacement Impeller with Gasket
2.
45042 – SLD Water Chamber Cover
SLD 5000-9000 Replacement Parts
No. Description
1.
45045 – SLD 5000-9000 Replacement Impeller with Gasket
2.
45042 – SLD Water Chamber Cover
☎
☎