Chtce ZHRV5 Series Instrucciones de uso

Navegue en línea o descargue pdf Instrucciones de uso para Relés Chtce ZHRV5 Series. Chtce ZHRV5 Series 2 páginas.

Operating Instructions for ZHRV5 Series Relay
Function Features
Controls its own supply voltage(True RMS measurement).
Set 8-level rated operating voltage through knob.
The relay is only 18mm wide.
Measuring frequency range:45Hz~65Hz.
Voltage measurement accuracy <1%.
Control status is indicated by a LED.
The relays are designed for clip-on mounting on
Applications
Control for connection of moving equipment (site equipment,agricultural
equipment, refrigerated trucks).
Control for protection of persons and equipment against the consequences
of reverse running.
Normal/emergency power supply switching.
Protection against the risk of a driving load (phase failure).
Model and Connotation
/
ZHRV5
Rated control supply voltage codes:
M460:220-230-240-380-400-415-440-460VAC
Function code(see Table 1)
ZHRV5 series relay
Function
Over-
Under-
code
voltage
voltage
03
04
05
2%...20%
06
-20%...2%
07
2%...20%
-20%...2%
-20%...2%
08
2%...20%
-20%...2%
09
2%...20%
10
2%...20%
-20%...2%
11
12
15%
-15%
Note:●the function is available
Technical Parameters
Rated supply voltage
220...460V AC 3phases
Supply voltage limits
176...552V AC
Control ciruit frequency
50/60Hz +/-10%
Voltage range
220-230-240-380-400-415-440-460V(P-P)
Threshold adjustment
2%...20%of Un selected
voltage
Adjustment of asymmetry
5%...15%
threshold
Time delay
Adjustable 0.1s...10s,10%
Measuring range
176...552V
Run up delay at power up
500ms time delay
Hysteresis
2%
Measurement error
<1%over the whole range with voltage variation
Reset delay
1000ms
Konb setting accuracy
1%of scale value
Phase failure sensitivity
0.7Un
R
rail.
Table1
Delay
Phase
Asymmetry
time
sequence
5%...15%
0.1s...10s
0.1s...10s
0.1s...10s
0.1s...10s
0.1s...10s
0.1s...10s
8%
2s
5%...15%
8%
2s
8%
2s
3-phase voltage monitoring relay
Voltage detection threshold
Rated insulation voltage
IP degree of protection
Pollution degree
Electrical durability
Mechanical durability
Height above sea level
Operation temperature
Relative humidity
Storage temperature
Conventional heat current
Utilisation category
Contact capacity
Output type
Connecting capacity
Tightening torques
Power consumption
Mounting support
Phase
Panel Diagram
failure
ZHRV5-03
R
R/T
ZHRV5-03
ZHRV5-06
R
R/T
Un
380
400
240
415
230
440
F1
460V
220
U<
-10 -12
-8
-14
-6
-16
F2
-4
-18
-20%
-2
Tt
6
4
2
8
0.1
10s
ZHRV5-06
1
Relay output and time delay LED.R/T
2
Rated voltage range selection knob.
3
Function LED.F1
4
Function LED.F2
5
Asymmetry rate adjust knob.Asy
6
Time delay adjust knob.Tt
7
Overvoltage setting knob.U>
8
Undevoltage setting knob.U<
-1-
Conform to:IEC60947-5-1standard
<165V
460V
IP20
3
100000 cycles
1000000 cycles
<=2000m
-5...40℃
<=50%(40℃)
-25...75℃
5A
AC-15
Ue/Ie:250V/1.5A
1 C/O
2
2
0.5mm ~2.5mm
0.5Nm
<=1.2VA
35mm symmetrical DIN rail conforming to
EN/IEC 60715
ZHRV5-04
ZHRV5-05
1
1
R
R/T
Un
400
Un
380
240
415
240
2
230
440
230
F1
460V
220
220
Asy
U>
10
8
12
6
F2
3
4
5
15%
2
Tt
6
Tt
4
4
2
2
8
0.1
10s
0.1
5
6
ZHRV5-04
ZHRV5-05
ZHRV5-07
ZHRV5-08
ZHRV5-10
ZHRV5-09
1
1
R
R/T
Un
380
400
Un
415
240
240
2
2
230
440
230
F1
460V
220
220
U>
U>
10 12
14
8
6
16
6
3
F2
3
4
18
4
2
20%
2
U<
U<
-10 -12
-8
-14
4
4
-6
-16
-6
-4
-4
-18
-20%
-2
-2
8
7
Tt
6
Asy
4
2
8
0.1
10s
5
6
8
ZHRV5-0 ●
ZHRV5-10
6
ZHRV5-11
ZHRV5-12
Un
240
230
220
ZHRV5-1 ●
1
R
R/T
400
380
415
2
440
F1
460V
10 12
8
14
16
F2
3
18
20%
6
4
4
8
10s
7
6
1
R
R/T
380
400
415
2
440
F1
460V
10 12
14
8
16
F2
3
18
20%
-10 -12
-8
-14
4
-16
-18
-20%
7
10
8
12
15%
8
5
1
R
R/T
380
400
415
2
440
F1
460V
F2
3
4