HP StorageWorks 8/8 - SAN Switch Nota de publicación - Página 25
Navegue en línea o descargue pdf Nota de publicación para Interruptor HP StorageWorks 8/8 - SAN Switch. HP StorageWorks 8/8 - SAN Switch 29 páginas. Hp storageworks fabric os 6.1.2b release notes (5697-0351, march 2010)
También para HP StorageWorks 8/8 - SAN Switch: Nota de publicación (30 páginas), Nota de publicación (43 páginas), Nota de publicación (32 páginas)
The aaaconfig command online help text needs to be corrected to
clearly indicate LDAP cannot be configured while FIPS is enabled.
FR-18i faulted after overnight stress testing.
A TI zone with an invalid (too high) port number can cause a kernel
panic.
ARRd Daemon had multiple restarts that ultimately let to a KSWD event.
Fast Write can obtain incorrect FCP command data length if the op-
tional additional CDB length is selected.
Hardware LED shows error status (flashing amber or green), even
though all FRUs are okay.
Invalid Tx/Rx rate can be computed if a polling cycle takes place when
a domain name has not been assigned.
An EZ Switch Manager validation error occurs on existing zones due
to devices of type initiator+target or unknown being treated like stor-
age.
The Accept CT_IU to GA_NXT Request frame is being rejected by a
third-party storage device because the frame size is 680 bytes.
HP 8/80 FRU faulty status not recovered after connecting to correct
power supply after operating with a single power supply.
A Tape Selective Reset error occurs due to incorrect handling of Early
End Synchronization status.
A FICON Device Level Ack Emulation Processing error occurred.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
HP StorageWorks Fabric OS 6.1.1b release notes
25