5. Filling: After completion of plumbing connections, remove fill-port cap using wrench provided and
pour neutralizer media into mineral tank using funnel provided (see below). DO NOT fill tank above the
line on the side of the media tank.
Overfilling the tank can result in neutralizer media entering the service lines. You may
have been provide more media than is required for the initial fill. Save this extra media
Open inlet valve and then turn water supply back on. Using a garden hose or bucket, fill unit with water
through fill-port. Replace fill-port cap.
6. Flush: Attach a garden hose to boiler drain (if installed) on outlet of the ATUN Series Upflow Acid
Neutralizer System. Discharge of hose should be into a bucket or drain. Open boiler drain and slowly
open inlet valve to flush the ATUN Series Upflow Acid Neutralizer System. Discharge water from hose will
be milky white due to fines generated during shipping and handling. Very fine particles of neutralizer
media may also be observed in the water. If "sand" like particles are observed, reduce flush flow rate
and then gradually increase. Continue to flush until discharge water runs clear. Upon completion of
flushing, close boiler drain and bypass valve and open outlet valve
7. IMPORTANT: If the home utilizes a tankless water heater, it is recommended that a water softener be
installed following the the ATUN Series Upflow Acid Neutralizer System. If the pH is initially over correct-
ed, the inlet bypass can be partially closed to mix untreated water with treated water to achieve the
desired level.
***Disclaimer*** United Water strongly recommends that each system be installed by a
licensed and knowledgeable professional. Failure to do so could result in property dam-
All systems MUST be installed in accordance with local and state plumbing codes.
Mainternance & Replenishing/Filling MEDIA:
The media in this the ATUN Series Upflow Acid Neutralizer System
is sacrificial, therefore it must be replenished periodically. The
frequency is dependent on the raw water pH and your water
consumption habits. The lower the pH and the higher the water
usage, the more frequently replenishment will be required. One
easy way of determining when to replenish is by placing a mark
on the outside of the tank at the level of the media when first
installed. Periodically shine a bright light through the tank and
compare the current level to the mark, if it is down more than
two (2) inches, add media to the mark. If you are unable to see
through the tank, remove the fill-port cap and measure down
to the top of the media. The tank should be 2/3 full. If not, add
media.
1) Close inlet and outlet valves. Open bypass valve so untreated
water can still be used during the replenishment operation.
2) Open boiler drain to relieve pressure. Remove fill-port cap
using wrench provided, some water will drain out of the fill-port
opening. Use a flexible tube to siphon approximately two gallons
of water from the tank.
3) Using the funnel provided, add the required amount of me-
dia, not to exceed the indicated line on the media tank. A bright
light may be placed behind the tank to observe the media level.
4) Refer to Steps 8-9 in Section 2 for flushing instructions to
complete the replenishment operation.
for future replenishment.