EE monitor counters may not get updated after performing switch-
disable/switchenble or reboot.
Static routing does not affect dynamic routes with DLS ON on supported
platforms.
The gzoneinfo.htm page returns empty data when CLI actually
shows defined/eff cfg zone info for fabric.
Third-party storage center application does not survive in an FCIP
network with 1% packet loss and 100 ms network latency.
Traffic Isolation failover policy reverts back to disabled from enabled
after changing the port membership list.
Hareboot on HP StorageWorks 400 Multi-protocol Router FC fastwrite
enabled switch causes the system to panic with "Oops: kernel access
of bad area, sig: 11 [#1]."
Fabric Mode TT displays redundant flows with different values for the
same SID/DID pair on the core switches when there are redundant
trunk groups to the same edge domain.
DLS ON does not rebalance when ISLs to a different switch are re-
moved on HP StorageWorks DC SAN Backbone Director and HP
StorageWorks 8/80 SAN Switch.
On an HP StorageWorks 8/80 SAN Switch, the system status LED
does not flash amber/green when a power supply is faulted.
User with admin role in some AD is able to add another user with
admin role in AD as ALL.
Reset to default button is grayed out always in SCSI vs. IP traffic setup
window.
USB Admin is not in sync with CLI when launched . It shows the correct
info only when we click refresh button.
Name Server database is being set with incorrect WWN's for NPIV
nodes when port ALPA = 0x13.
Potential timeouts and aborts during Device Discovery and CU busy
processing when using FICON XRC Emulation.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Retrieve all EE monitors from the
FLASH by issuing perfcfgrestore.
All EE monitor counters will be prop-
erly updated.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Do any other HTTP post operation
from DCFM and then you see both
the old data and the newly pushed
zone info. Rebooting the switch
sometimes helps.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Perform switchdisable and
switchenable to force a rebalance
of the routes.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Port ALPA must be set to default value
of 0x00 for ports hosting NPIV nodes.
Fixed in Fabric OS 6.2.0.