Closed issues from Fabric OS 4.4.0d
Table 8
lists issues resolved with the release of Fabric OS version 4.4.0d.
Table 8
Fabric OS 4.4.0d closed issues summary
Closed defect
Issue:
"Switch bring-up timed out "
during hot code load
Symptom: SAN Director 2/128,
Switch bring-up timed out <<-- HA
timed out hashow: Local CP (Slot 6,
CP1): Active Remote CP (Slot 5,
CP0): Standby, Healthy HA
enabled, Heartbeat Up, HA State
not in sync Solution: After failover,
the EVMD needs to connect to the
clients that were connected to the
switch before the failover. EVMD is
trying to establish the connections
before failover completes.
Issue: Disabling an active zone via
cfgDisbale disrupts Fiber
Channel IO.
Symptom: cfgDisable about
3500 Fibre Channel frame loss on
point to point traffic.
Issue: "Zoning transaction aborted"
is logged as error message caused
by 3rd party application call home.
Symptom: 3rd party application
call home when application probes
zone and aborts the transaction
intentionally.
Issue: API returns error
intermittently when trying to
establish a session with the proxy
switch when Fabric Manager tries
to retrieve Port Stats and
End-to-End Monitoring.
Symptom: When Fabric Manager
uses API, it returns -21 error code
when the
FabAPI_EstablishFabricSessionEx
call is being made.
40
Closed issues from Fabric OS 4.4.0d
Status
Fixed
Fixed
Fixed
Fixed