Displaying Power Supply Status
To display the power supply status of a switch:
1.
Login to the switch as the admin user.
2.
At the command line enter the following command:
psShow
The possible values for power supply status are:
OK - Power supply present and functioning correctly.
absent - Power supply not present.
faulty - Power supply present but faulty (no power cable, power switch turned off, fuse
blown, or other internal error).
After the status line, a power supply identification line may be shown. If present, this line
contains manufacture date, part numbers, serial numbers, and other identification information.