Jandy™ & Compool™ Connections
for Compool
Attach the 2 wire cable to the Compool's power center board located on the
terminals labeled "HTR" *See the controllers installation guide also.
for AquaLink RS
cable to positions #1 and position # 2
on the 10 slot, green terminal bar inside
the AquaLink's power center. *See the
controllers installation guide also.
OR
OR
OR
AQUASWITCH or JI2000
First, remove the black wire located in position # 2 on the black terminal bar and cap. Do not
remove any other factory wires that may share the same positions as the 3 wire cable.
NOTE: Other non
thermostat type of
controls hook up the
same way shown
here.
The control will uti-
lize the heaters t-
stats, the control will
switch between pool
and spa t-stat.
Leave the heater's
switch in pool mode.
Next, attach the 3 wire cable
to the HEATER on the black
terminal bar as follows:
#2 COMMON
#3 LOW/POOL
#4 HIGH/SPA
*See the controller's installation guide also.
Attach the 2 wire
OR
12 11 10 9 8
Attach the other end of the 3 wire
cable to the JI2000 as follows:
#10 For the HIGH/SPA
#11 For the LOW/POOL
#12 For the COMMON
for "Prologic" Analog Control Models
OR
7 6 5 4 3 2
1
1
2
3
4
5
6
7
8
9
10
11
12
Attach the other end of the 3
wire cable to the
AquaSwitch as follows:
#12 For the HIGH/SPA
#13 For the COMMON
#14 For the LOW/POOL
OR
OR
NOTE: The control
will have thermostat
control over heater.
Turn the heater's t-
stats all the way up
and leave the switch
in pool mode.