Panasonic PT-EX16KU Manual de instrucciones - Página 23
Navegue en línea o descargue pdf Manual de instrucciones para Proyector Panasonic PT-EX16KU. Panasonic PT-EX16KU 27 páginas. Brochure
También para Panasonic PT-EX16KU: Especificaciones (16 páginas), Folleto (4 páginas)
PJLink protocol
The network function of the projector supports PJLink class 1, and the PJLink protocol can be used to perform
projector setting and projector status query operations from a computer.
Control commands
The following table lists the PJLink protocol commands that can be used to control the projector.
Command
Control details
POWR
Power supply control
POWR ?
Power supply status query
INPT
Input selection
INPT ?
Input selection query
AVMT
AV MUTE control
AVMT ?
AV MUTE status query
ERST ?
Error status query
Lamp status query
LAMP ?
Input selection list query
INST ?
NAME ?
Projector name query
INF1 ?
Manufacturer name query
INF2 ?
Model name query
INF0 ?
Other information query
CLSS ?
Class information query
PJLink security authorization
When using PJLink with security authorization, either of the password set for administrator privileges and the
password set for user privileges with Web browser control can be used as the password for PJLink (See page 16).
When using PJLink without security authorization, set use without the password for administrator privileges and the
password for user privileges of Web browser control.
For specifications regarding PJLink, refer to the Japan Business Machine and Information System Industries
Association website.
URL http://pjlink.jbmia.or.jp/
Parameters
0 = Standby
1 = Power ON
Parameters
0 = Standby
1 = Power ON
2 = Cool-down in progress
Parameters
11:RGB 1 12:RGB 2 31:DIGITAL 1 32: DIGITAL 2 33: DIGITAL 3
46:AUX1 21:VIDEO 1 22:VIDEO 2 13:RGB 3 25: VIDEO 5
47:AUX2 48:AUX3 49:AUX4
Parameters
30 = AV MUTE mode off
31 = AV MUTE mode on
Parameters
1st byte : Indicates fan errors, range 0 – 2
2nd byte : Indicates lamp errors, range 0 – 2
3rd byte : Indicates temperature errors, range 0 – 2
4th byte : Fixed at 0
5th byte : Indicates filter errors, range 0 – 2
6th byte : Indicates other errors, range 0 – 2
Definitions for each value from 0 to 2 are as follows.
0 = No error known
Parameters
1st digits (1 – 5 digits) : Lamp cumulative operating time
2nd digit : 0 = Lamp off, 1 = Lamp on
The following are returned as parameters.
" 11 12 31 32 33 21 22 13 25 46 47 48 49"
The name set for [NAME CHANGE] in [NETWORK] is returned.
"Panasonic" is returned.
Answer the model name with EX16K
Information such as version number is returned.
"1" is returned.
Notes
1 = Warning
2 = Error
23